Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add filters








Year range
1.
Japanese Journal of Cardiovascular Surgery ; : 345-349, 1996.
Article in Japanese | WPRIM | ID: wpr-366252

ABSTRACT

Transcatheter embolization of 25 aortopulmonary collateral arteries (7 bronchial arteries and 18 intercostal arteries) was attempted prior to intracardiac repair in 7 patients. The underlying disease was tetralogy of Fallot in 3 patients, pulmonary atresia with ventricular septal defect in 2, double-outlet right ventricle with ventricular septal defect and pulmonary stenosis in 1 and tricuspid stenosis with pulmonary atresia in 1. The intervals between embolization and intracardiac repair ranged from 0 to 17 days (mean 4.5 days). Embolization resulted in total occlusion in 7 bronchial arteries and 17 intercostal arteries, with an overall success rate of 96%. Complications included a coil dislodgement from a collateral artery into the aorta in one patient, necessitating surgical removal of the dislodged coil from the femoral artery, an exacerbation of cyanosis and dyspnea on exercise in 5, and slight fever in 2. In one patient with tetralogy of Fallot, who had 5 collateral vessels, transcatheter embolization caused hypoxemia, bradycardia and hypotension and therefore intracardiac repair was performed immediately after embolization. Aortopulmonary collateral arteries in patients with congenital heart disease can be effectively treated by transcatheter embolization. Embolization should be performed just before intracardiac repair because an excessive decrease in arterial oxygen saturation after embolization may require an emergency operation.

2.
Japanese Journal of Cardiovascular Surgery ; : 139-151, 1994.
Article in Japanese | WPRIM | ID: wpr-366029

ABSTRACT

This multicenter study was designed to clarify the positive effects of recombinant human erythropoietin (EPO; epoetin alfa) by subcutaneous administration on anemia after autologous blood donation in cardiac surgery. A total of 55 patients undergoing elective heart surgery were enrolled in this study and subcutaneously given EPO at a dose of 200IU/kg (200IU group, <i>n</i>=23), 400IU/kg (400IU group, <i>n</i>=16) or 600IU/kg (600IU group, <i>n</i>=16) once a week for 3 weeks prior to surgery. Autologous blood (400g) was drawn twice from each patient, at 14 days and 7 days before surgery. Oral iron was given daily throughout this study. The mean reticulocyte counts increased significantly 2 weeks after the first administration of EPO in the 200IU group or 1 week after the first administration in the 400IU and 600IU groups. There was an increase in mean hemoglobin (Hb) levels 1 week after the initiation of EPO by 1.7, 2.8 and 2.1% in the 200IU, 400IU and 600IU groups, respectively. After the first drawing of autologous blood, the Hb levels decreased gradually in all groups despite the second administration of EPO. The change in Hb level immediately before surgery however, was a 4.2% decrease (<i>p</i><0.05) in the 200IU group and 0.8% decrease (N. S.) in the 400IU group and 0.7% increase (N. S.) in the 600IU group in comparison with the initial Hb level. In conclusion, subcutaneous administration of EPO was effective in improving anemia after autologous blood donation in cardiac surgery.

3.
Japanese Journal of Cardiovascular Surgery ; : 73-77, 1994.
Article in Japanese | WPRIM | ID: wpr-366023

ABSTRACT

Thirty-four patients with congenital cardiac disease were studied to evaluated the role of ultrafiltration after cardiopulmonary bypass without homologous blood transfusion. We used either polypropylene microporous hollow fiber hemoconcentrator (HC-30M or 100M) or polyacrylonitrile microporous hollow fiber hemoconcentrator (PHC-500). Ultrafiltration was useful in the reduction of fluid overloading after cardiopulmonary bypass with extreme hemodilution. Thirty-two patients tolerated the procedure uneventfully without donor blood transfusion and were discharged from the hospital. The values of hematocrit, serum protein and free hemoglobin increased significantly after ultrafiltration with either type of hemoconcentrator. However the degree of concentration of blood components was significantly higher with polyacrylonitrile hemoconcentrator than those with polypropylene hemoconcentrator. These results indicated that ultrafiltration was useful for maintaining water balance after cardiopulmonary bypass without homologous blood transfusion in pediatric cardiac surgery and that polyacrylonitrile microporous hollow fiber hemoconcentrator should be employed in patients with shorter bypass time and less hemolysis.

4.
Japanese Journal of Cardiovascular Surgery ; : 28-32, 1994.
Article in Japanese | WPRIM | ID: wpr-366003

ABSTRACT

Ascending aorta-infrarenal abdominal aorta bypass was performed in 8 patients: 4 patients with dissecting aortic aneurysm, 3 patients with thoracic aneurysm and 1 patient with stenosis of the thoracic aorta after grafting for congenital thoracic aneurysm. Four patients who had aortic dissection underwent the thromboexclusion method, but thromboexclusion of the thoracic aorta occured in only one patient after additional clamp to the distal thoracic aorta. He is the only long-term survival in this series. The thromboexclusion method was also performed in two patients with infectious thoracic aortic aneurysm, but they died of aneurysmal rupture within 13 months after operation. One patient who undewent resection of a thoracic aneurysm with extra-anatomic bypass, developed respiratory insufficiency and paraplegia, and died of pneumonia. The patient with thoracic aortic stenosis is alive and well 11 years after operation. The indications of the thromboexclusion method for thoracic aneurysm should be limited only to very poor-risk patients who seem to be inaccessible to a direct approach. Ascending aorta-abdominal aorta bypass is recommended in cases of thoracic aortic stenosis.

5.
Japanese Journal of Cardiovascular Surgery ; : 334-338, 1993.
Article in Japanese | WPRIM | ID: wpr-365957

ABSTRACT

Five patients with isolated stenosis of the left main coronary artery or stenotic ostial lesions underwent direct coronary artery surgery. These surgical approaches included vein patch angioplasty in 2 cases, punch out endarterectomy in 1 case, and resection of the thickened aortic wall and transaortic endarterectomy in 2 cases. Early results were satisfactory, except for one case who died due to severe LOS and MOF. In the late postoperative period, one case of vein patch angioplasty died due to cerebral bleeding, and in the other case, stenosis existed in position of distal patch anastomosis. Since direct coronary artery surgery was successful in both early and late postoperative fidings, it is believed to be useful and safe technique if the candidates are selected properly.

6.
Japanese Journal of Cardiovascular Surgery ; : 605-608, 1992.
Article in Japanese | WPRIM | ID: wpr-365871

ABSTRACT

A case of 65-year-old man of aorto-caval fistula induced by ruptured abdominal aortic aneurysm is reported. The symptoms were hematuria and chest pain, and an emergent operation was performed. In the operation, Fogarty's balloon occlusion catheter was used to reduce bleeding from inferior <i>vena cava</i>, and to prevent pulmonary embolism. The fistula was 3cm in size, and abdominal aorta was replaced with a low porosity polyester Y-graft. The symptoms of pulmonary congestion and hematuria were improved after operation. The balloon occlusion catheter was effective for reducing bleeding from IVC, and prevention from pulmonary embolism after operation.

7.
Japanese Journal of Cardiovascular Surgery ; : 515-518, 1992.
Article in Japanese | WPRIM | ID: wpr-365853

ABSTRACT

We applied a new circulatory support system to three patients with descending aortic operation between 1989 and 1990. The new system consisted of a polyvinylchloride tube coated with hydrophilic heparinized polymer and a roller pump. Low doses of heparin (0.5mg/kg) were administered in two patients and none in one patient before aortic bypass. The aortic crossclamping time ranged between 52 and 64 minutes. In two patients, whose inflow cannulae were 18Fr. or 20Fr., successful bypass flow exceeded 2<i>l</i>/min and optimal distal aortic pressure were maintained during aortic cross-clamping. The postoperative courses of these patients were uneventful, free from thromboembolic episodes and subsequently discharged from hospital. Furthermore, postoperative careful examination revealed no thrombus formation occurred in the three devices. In conclusion, our new simple, antithrombogenic circulatory system is extremely useful for descending aortic operations.

8.
Japanese Journal of Cardiovascular Surgery ; : 510-514, 1992.
Article in Japanese | WPRIM | ID: wpr-365852

ABSTRACT

A 47 year-old man with frequent attacks of ventricular tachycardia (VT) due to arrhythmogenic right ventricular dysplasia (ARVD) developed severe right heart failure following cryoablation of the multiple VT focuses. Inotropic support and intraaortic balloon pumping failed to maintain the systemic circulation, so that we performed the right heart bypass (RHB) using a heparin-coated tube and roller pump. With the use of RHB, systemic circulation improved. We attempted to wean the patient off after 14 days RHB support. However this was unsuccessful because of poor RV function, and RHB was recommenced. The patient finally died of multiple organ failure on the 21st postoperative day, but the major organ function was well maintained for at least two weeks. The heparin-coated tube and roller pump system is easy to handle, and is suitable as a short term lifesaving adjunct for severe right ventricular failure.

9.
Japanese Journal of Cardiovascular Surgery ; : 447-451, 1992.
Article in Japanese | WPRIM | ID: wpr-365840

ABSTRACT

To estimate the blood compatibility during extracorporeal circulation, we designed mock circulation system consisted of a membrane oxygenator and vinyl circuit with roller pump. Primed with 200ml Ringer's acetate and 200ml of fresh whole human blood, mock circulation was worked at flow rate 0.5<i>l</i>/min for 6hr. Heparin was not primed, oxygenator did not fill any gases and circulation was keeping at 37°C. The thrombin-antthrombin complex and fibrinopeptide-A showed progressive increase and fibrinogen correspondingly decrease. Nevertheless, the plasmin α2 plasmin inhibitor complex and D-dimer showed minimal changes within normal range in spite of increasing fibrinopeptide B β 15-42. We can not find any signs of secondary fibrinolytic activity. On the other hand, the platelet was persistently activated as shown statistically significant increase in β-thrombogloblin and platelet factor IV. Significant elevations of complement 3a and 4a were seen with increase of complement 5a and activated oxygen productivity by neutrophilic leucocytes. In conclusion, moderate and limited blood alterations occurred in mock cardiopulmonary bypass circuit.